Special requirements for the Reclaim Energy Co2 hot water system

The Reclaim Energy CO₂ Hot Water System requires specific spatial considerations for both the heat pump unit and the hot water storage tank to ensure efficient performance and easy maintenance. Here's an overview of the space requirements:

1. Heat Pump Unit

The heat pump unit is responsible for extracting heat from the surrounding air and transferring it to the water in the storage tank. Proper placement is crucial for both airflow and noise management.

Outdoor Placement:

  • Location: The heat pump unit is usually installed outdoors, as it needs to access ambient air for heat extraction.

  • Clearance for Airflow:

    • It should have at least 1 meter (3 feet) of clearance in front of the unit and 30-50 cm (1-1.5 feet) on each side to allow for unrestricted airflow. Blocked airflow could reduce the system's efficiency.

    • The unit should not be installed in confined spaces, such as under a low deck or in a small enclosed area, as this can cause overheating or inefficient performance.

Mounting Options:

  • The heat pump unit can be mounted on the ground or on brackets attached to the wall. When wall-mounted, the bottom of the unit should be about 60-70 cm (2 feet) above the ground to prevent obstructions like snow, debris, or plants.

Noise Considerations:

  • While Reclaim CO₂ heat pumps operate quietly, it's still advisable to install the unit away from bedroom windows or other noise-sensitive areas, especially in smaller properties.

2. Hot Water Storage Tank

The hot water storage tank is where the heated water is stored for use. The tank's size will affect the space requirements.

Indoor or Outdoor Installation:

  • The Reclaim 300L hot water tank can be installed either indoors or outdoors, depending on available space. Ensure it is placed on a solid, level surface, and if installed outdoors, it should be sheltered from direct sunlight or rain.

Dimensions:

  • For the 300L tank, the dimensions are typically around:

    • Height: Approximately 1.8 meters (6 feet)

    • Diameter: Around 600-700 mm (24-28 inches)

Clearance Requirements:

  • Ensure there is enough space around the tank for maintenance and inspection, typically 500 mm (1.5 feet) clearance around the unit, especially near valves and connections.

  • The tank should also be easily accessible for any potential future replacements or repairs.

3. Plumbing and Electrical Requirements

  • Proximity to Heat Pump: The tank should be placed within a reasonable distance of the heat pump unit to minimize heat loss. Ideally, the piping between the two components should be well-insulated, and the distance should be kept as short as possible to maximize energy efficiency.

  • Electrical Requirements: The system will need a dedicated power supply. The electrical connection should be close to the heat pump unit, with proper weatherproofing if installed outdoors.

4. Ventilation

  • Good Airflow for Heat Pump: Ensure the location of the heat pump allows for adequate ventilation. Installing the unit in a poorly ventilated area or near exhaust vents from other appliances can impact efficiency.

5. Ground Mounting and Drainage

  • Drainage Consideration: Ensure that there is adequate drainage around the heat pump unit, especially if installed on the ground. The system will occasionally produce condensation, so it is important that water can drain away properly without pooling around the unit.

  • Mounting Surface: Both the heat pump and the water tank should be placed on a level, sturdy surface that can support their weight, especially when the tank is full of water.


Summary of Spatial Requirements:

  1. Heat Pump Unit:

    • 1 meter (3 feet) of clearance at the front and 30-50 cm (1-1.5 feet) around the sides.

    • Located outdoors, with good airflow and clear of obstructions.

    • Noise considerations: install away from sensitive areas.

  2. Hot Water Tank (300L model):

    • Height: ~1.8 meters (6 feet); Diameter: ~600-700 mm (24-28 inches).

    • Clearance of 500 mm (1.5 feet) around the unit for maintenance.

    • Installed on a sturdy, level surface, either indoors or outdoors.

  3. Distance Between Components:

    • Minimize distance between heat pump unit and storage tank to reduce heat loss and improve efficiency.

Ensuring these space requirements are met will allow the Reclaim Energy CO₂ Hot Water System to operate efficiently and effectively for your household or business needs.

Hot Water Solutions logo

Hot Water Solutions

Address: 3d Tait Place, Rosedale, Auckland 0632, New Zealand

Phone: 0800497658

Email: info@hotwatersolutions.nz

Website: https://hotwatersolutions.nz/

Location: https://maps.app.goo.gl/1PErGDvtptttvYQY6

Follow us: https://www.instagram.com/pete_hotwatersolutions/


No comments:

Post a Comment

Special requirements for the Reclaim Energy Co2 hot water system

The Reclaim Energy CO₂ Hot Water System requires specific spatial considerations for both the heat pump unit and the hot water storage tan...